AquaProtect-Duo High Capacity Technical Data Sheet
AquaProtect-Duo High Capacity (GC)
High-capacity general filtration and limescale protection at the point of entry


Principle
AquaProtect-Duo High Capacity provides filtration and scale protection for commercial and residential systems and equipment. It combines two 20-inch Big Blue filtration stages with a passive treatment RING installed at the module’s outlet.
|
1. Sediments 5 µm |
Compact polypropylene depth filtration cartridge: reduces sludge, rust, oxides, fine sand, and suspended particles. |
|
2. BLOCK 10 µm Activated Carbon |
High-capacity compressed structure: reduces chlorine, tastes, odors, many organic compounds, and certain PFAS, depending on the quality of the media and operating conditions. |
|
3. RING |
An external, passive device that does not come into contact with water and does not reduce the pipe’s cross-sectional area. It must be selected based on the actual outer diameter of the outlet pipe. |
Features and Benefits: Tangible Advantages in Everyday Life
• Reduction in airborne particulate matter.
• Reduction of chlorine, tastes, odors, organic compounds, and certain PFAS.
• Large capacity and long runtime thanks to the 20-inch Big Blue format.
• Reduces scale buildup in systems.
• Protection of pipes, valves, and equipment.
• No chemicals added to the water and no electrical connection required.
• Helps reduce maintenance and upkeep costs.
Functional Diagram: Network-Specific Configuration
The module is installed at the inlet, preferably on a bypass. The RING is included, but its diameter must be configured based on the actual measurement of the outlet pipe.
Key Features
|
Parameter |
Specifications |
|
Configuration |
Set of 2 Big Blue 20-inch Filter Holders + RING |
|
1st floor |
5 µm compact polypropylene |
|
2nd floor |
High-capacity BLOCK activated carbon, nominal 10 µm |
|
Installation |
Entry point - vertical installation - bypass recommended |
|
RING |
External output mounting—no pressure drop |
|
Energy |
Passive operation, no electricity required |
|
Recommended water temperature |
5 to 40 °C |
Hydraulic Data and Maintenance
Indicative Initial Pressure Drops
The values below are estimates based on two new 20-inch Big Blue cartridges, clean water at approximately 20 °C, and properly sized connections.
|
Flow Rate |
Compact PP 5 µm |
BLOCK Charcoal 10 µm |
2 filter holders |
RING |
Estimated total |
|
10 L/min |
0.01 bar |
0.10 bar |
0.01 bar |
0 bar |
0.12 bar |
|
15 L/min |
0.01 bar |
0.15 bar |
0.02 bar |
0 bar |
0.18 bar |
|
20 L/min |
0.02 bar |
0.20 bar |
0.03 bar |
0 bar |
0.25 bar |
|
25 L/min |
0.02 bar |
0.26 bar |
0.04 bar |
0 bar |
0.32 bar |
|
30 L/min |
0.03 bar |
0.31 bar |
0.05 bar |
0 bar |
0.39 bar |
|
35 L/min |
0.03 bar |
0.36 bar |
0.06 bar |
0 bar |
0.45 bar |
|
40 L/min |
0.04 bar |
0.41 bar |
0.08 bar |
0 bar |
0.53 bar |
Recommended flow rate: 20 to 30 L/min to maintain a good balance between flow rate, pressure drop, and contact time with the activated carbon. Occasional flow rates of up to approximately 40 L/min are possible,
Maintenance
• Check the pressure upstream and downstream of the module regularly.
• Replace the cartridges based on usage, water quality, and an increase in pressure drop.
• As a general guideline: replace every 6 to 12 months, depending on professional use.
• Rinse the carbon cartridge thoroughly when putting it into service.
• The RING requires no consumables and causes no hydraulic pressure drop.
Installation Recommendations
• Install on a bypass to allow for maintenance without a prolonged power outage.
• Install shut-off valves and drain valves, and ensure there is sufficient space under the bowls to replace the cartridges.
• Install in a frost-free location, out of direct sunlight, and on a wall capable of supporting the unit’s operating weight.
• Follow the traffic direction indicated on .
• Measure the outer diameter of the outlet pipe before selecting the RING.
Osmodyn® - Filter. Protect. Optimize for the long term. www.osmodyn.com